Press shutter release button again error with high F values only

Guillermo ESP

New member
Hi everyone,I bought a used but almost new D3300 with faulty SD connetor. In the end, I have had to replace the main board and the power one.
Now the camera works but when the diaphragm is F10 or higher values error "press shutter release button again" appears.
I thought it was only in auto mode, but in manual if I set it to F10, for example, the error appears too.
The lens is the standard 18-55 and I checked that the diaphragm lever moves softly. But the lever in the body (that is on the left when you look from the front with no lens) moves freely but I think the spring is quite strong to be moved quickly with an electronic mechanism.
Would anyone be so kind and move this lever to check if it moves easily or needs quite more strength that the one in the lens? Or any other reason for the problem you could think of?
Thanks so much in advance,
 

Attachments

  • nikonfix.jpg
    nikonfix.jpg
    110.5 KB · Views: 151

Marcel

Happily retired
Staff member
Super Mod
Welcome to the forum Guillermo.

Please remember that we are in no way associated to Nikon nor are we a repair consulting forum. We are just a bunch of friends trying to help each others. Sometimes, if a problem was solved by a member, one can get answers to his problems. But sometimes when no one knows how to solve, they will just not respond. Since the D3300 is an older model, it's difficult to know how many members of our forum have this model. So if you don't get an answer to your problem, maybe you will have to contact Nikon support for service.

Hope this helps

Enjoy your Nikon.
 

Guillermo ESP

New member
Hi and thank you,
Of course I assume it completely. It's just to get any idea in case someone has been in the same situation.
By the way, I could test with a different D3300 and lens and the problem is in the body. And the mentioned spring moves just the same way.
I don't know if I'll manage to get a solution :-(

Regards,
Guillermo
 
Top